Search Results (2042 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-104611 1 Tenda 2 Ac9, Ac9 Firmware 2026-10-02 9.1 Critical
A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
CVE-2026-104610 1 Tenda 3 Hg10, Hg7, Hg9 2026-10-02 10 Critical
A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
CVE-2026-11553 1 Tenda 4 Hg10, Hg7, Hg7hg9 and 1 more 2026-10-02 8.8 High
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
CVE-2026-11499 1 Tenda 4 Hg10, Hg7, Hg7hg9 and 1 more 2026-10-02 9.8 Critical
A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
CVE-2026-11498 1 Tenda 4 Hg10, Hg7, Hg7hg9 and 1 more 2026-10-02 8.8 High
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
CVE-2018-25318 1 Tenda 5 A300, A300 Firmware, Fh303 and 2 more 2026-10-01 9.8 Critical
Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin cookie to change DNS servers and redirect user traffic to malicious sites.
CVE-2026-38142 1 Tenda 1 Ac18 2026-09-30 6.5 Medium
An unauthenticated command injection vulnerability in the /goform/fast_setting_internet_set endpoint of Tenda AC18 v15.03.05.05 allows attackers to execute arbitrary commands via a crafted payload injected into the mac parameter.
CVE-2026-90688 1 Tenda 2 W20e, W20e Firmware 2026-09-15 6.5 Medium
A vulnerability was identified in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. This issue affects the function formIPMacBindAdd of the component HTTP Handler. Such manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to launch the attack remotely.
CVE-2026-90689 1 Tenda 2 W20e, W20e Firmware 2026-09-14 8.8 High
A security flaw has been discovered in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. Impacted is the function formDelWebAuthWhiteUser. Performing a manipulation of the argument webAuthWhiteUserIndex results in stack-based buffer overflow. The attack can be initiated remotely.
CVE-2026-86166 1 Tenda 2 Hg10, Hg10 Firmware 2026-09-11 8.8 High
A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2026-86151 1 Tenda 2 Cp3, Cp3 Firmware 2026-09-11 9.1 Critical
A vulnerability was detected in Tenda CP3 27.5.57.101. The affected element is the function sub_2F77E8 of the file Apis/system.c of the component Network Configuration Management. Performing a manipulation results in os command injection. The attack may be initiated remotely.
CVE-2026-86152 1 Tenda 2 Cp3, Cp3 Firmware 2026-09-10 10 Critical
A flaw has been found in Tenda CP3 27.5.57.101. The impacted element is the function CAutoAddWifi::ThreadProc of the file Functions/AutoAddWifi.cpp of the component Kylin. Executing a manipulation can lead to os command injection. The attack may be launched remotely.
CVE-2026-86167 1 Tenda 2 Hg10, Hg10 Firmware 2026-09-08 9.9 Critical
A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CVE-2026-86148 1 Tenda 2 Cp3, Cp3 Firmware 2026-09-08 9.1 Critical
A security flaw has been discovered in Tenda CP3 27.5.57.101. This vulnerability affects the function SystemAsh of the file Apis/system.c of the component Kylin. The manipulation of the argument AlarmVoiceURL results in os command injection. It is possible to launch the attack remotely.
CVE-2026-86300 1 Tenda 2 Ac9, Ac9 Firmware 2026-09-08 7.3 High
A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used.
CVE-2026-86165 1 Tenda 2 Hg10, Hg10 Firmware 2026-09-08 9.8 Critical
A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
CVE-2026-86150 1 Tenda 2 Cp3, Cp3 Firmware 2026-09-08 4.1 Medium
A security vulnerability has been detected in Tenda CP3 27.5.57.101. Impacted is an unknown function of the file custom-x/softap/hostapd. Such manipulation of the argument wpa_passphrase leads to hard-coded credentials. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CVE-2026-86153 1 Tenda 2 Cp3, Cp3 Firmware 2026-09-06 9.1 Critical
A vulnerability has been found in Tenda CP3 27.5.57.101. This affects the function CRedirServer::SetRedirectEnable of the file Functions/Redirect.cpp. The manipulation leads to improper privilege management. Remote exploitation of the attack is possible.
CVE-2026-86149 1 Tenda 2 Cp3, Cp3 Firmware 2026-09-05 9.1 Critical
A weakness has been identified in Tenda CP3 27.5.57.101. This issue affects some unknown processing of the file Net/NetCheckPing.cpp. This manipulation of the argument interface_name/host causes os command injection. The attack can be initiated remotely.
CVE-2026-51934 1 Tenda 1 A18 2026-09-03 9.8 Critical
Buffer Overflow vulnerability in Shenzhen Jixiang Tengda Technology Co., Ltd. Tenda A18 v.15.13.07.09 allows a remote attacker to execute arbitrary code via the fromSetCmdlineRun function