CVE-2025-59102 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device.
CVE-2025-59105 1 Dormakaba 1 Access Manager 2026-04-15 N/A
With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.
CVE-2025-58401 2026-04-15 N/A
Obsidian GitHub Copilot Plugin versions prior to 1.1.7 store Github API token in cleartext form. As a result, an attacker may perform unauthorized operations on the linked Github account.
CVE-2025-53758 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device.
CVE-2025-53755 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted data stored in the firmware of targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the network of the targeted device.
CVE-2025-53103 2026-04-15 5.8 Medium
JUnit is a testing framework for Java and the JVM. From version 5.12.0 to 5.13.1, JUnit's support for writing Open Test Reporting XML files can leak Git credentials. The impact depends on the level of the access token exposed through the OpenTestReportGeneratingListener. If these test reports are published or stored anywhere public, then there is the possibility that a rouge attacker can steal the token and perform elevated actions by impersonating the user or app. This issue as been patched in version 5.13.2.
CVE-2025-41647 2026-04-15 5.5 Medium
A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-40752 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-30124 1 Marbella 1 Kr8s Dashcam 2026-04-15 9.8 Critical
An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. When a new SD card is inserted into the dashcam, the existing password is written onto the SD card in cleartext automatically. An attacker with temporary access to the dashcam can switch the SD card to steal this password.
CVE-2025-23027 2026-04-15 N/A
next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems.
CVE-2025-2182 1 Palo Alto Networks 1 Pan-os 2026-04-15 N/A
A problem with the implementation of the MACsec protocol in Palo Alto Networks PAN-OS® results in the cleartext exposure of the connectivity association key (CAK). This issue is only applicable to PA-7500 Series devices which are in an NGFW cluster. A user who possesses this key can read messages being sent between devices in a NGFW Cluster. There is no impact in non-clustered firewalls or clusters of firewalls that do not enable MACsec.
CVE-2025-2181 1 Paloaltonetworks 1 Checkov 2026-04-15 N/A
A sensitive information disclosure vulnerability in Palo Alto Networks Checkov by Prisma® Cloud can result in the cleartext exposure of Prisma Cloud access keys in Checkov's output.
CVE-2025-0142 2026-04-15 4.3 Medium
Cleartext storage of sensitive information in the Zoom Jenkins Marketplace plugin before version 1.4 may allow an authenticated user to conduct a disclosure of information via network access.
CVE-2025-0123 1 Paloaltonetworks 1 Pan-os 2026-04-15 N/A
A vulnerability in the Palo Alto Networks PAN-OS® software enables unlicensed administrators to view clear-text data captured using the packet capture feature https://docs.paloaltonetworks.com/pan-os/11-0/pan-os-admin/monitoring/take-packet-captures/take-a-custom-packet-capture in decrypted HTTP/2 data streams traversing network interfaces on the firewall. HTTP/1.1 data streams are not impacted. In normal conditions, decrypted packet captures are available to firewall administrators after they obtain and install a free Decryption Port Mirror license. The license requirement ensures that this feature can only be used after approved personnel purposefully activate the license. For more information, review how to configure decryption port mirroring https://docs.paloaltonetworks.com/network-security/decryption/administration/monitoring-decryption/configure-decryption-port-mirroring . The administrator must obtain network access to the management interface (web, SSH, console, or telnet) and successfully authenticate to exploit this issue. Risk of this issue can be greatly reduced by restricting access to the management interface to only trusted administrators and from only internal IP addresses according to our recommended critical deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . Customer firewall administrators do not have access to the packet capture feature in Cloud NGFW. This feature is available only to authorized Palo Alto Networks personnel permitted to perform troubleshooting. Prisma® Access is not impacted by this vulnerability.
CVE-2024-9991 1 Signify Innovations India 7 Phillips Smart Bulb 10-watt Firmware, Phillips Smart Bulb 12-watt Firmware, Phillips Smart Bulb 9-watt Firmware and 4 more 2026-04-15 N/A
This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected.
CVE-2024-9432 1 Opentext 1 Vertica 2026-04-15 N/A
Cleartext Storage of Sensitive Information vulnerability in OpenText™ Vertica allows Retrieve Embedded Sensitive Data.   The vulnerability could read Vertica agent plaintext apikey.This issue affects Vertica versions: 23.X, 24.X, 25.X.
CVE-2024-8070 2026-04-15 8.5 High
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test credentials in the firmware binary
CVE-2023-49113 1 Kiuwan 1 Local Analyzer 2026-04-15 7.8 High
The Kiuwan Local Analyzer (KLA) Java scanning application contains several hard-coded secrets in plain text format. In some cases, this can potentially compromise the confidentiality of the scan results. Several credentials were found in the JAR files of the Kiuwan Local Analyzer. The JAR file "lib.engine/insight/optimyth-insight.jar" contains the file "InsightServicesConfig.properties", which has the configuration tokens "insight.github.user" as well as "insight.github.password" prefilled with credentials. At least the specified username corresponds to a valid GitHub account. The JAR file "lib.engine/insight/optimyth-insight.jar" also contains the file "es/als/security/Encryptor.properties", in which the key used for encrypting the results of any performed scan. This issue affects Kiuwan SAST: <master.1808.p685.q13371
CVE-2024-53651 2026-04-15 4.6 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.