Search Results (693 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-39395 1 Sigstore 1 Cosign 2026-04-15 4.3 Medium
Cosign provides code signing and transparency for containers and binaries. Prior to 3.0.6 and 2.6.3, cosign verify-blob-attestation may erroneously report a "Verified OK" result for attestations with malformed payloads or mismatched predicate types. For old-format bundles and detached signatures, this was due to a logic flaw in the error handling of the predicate type validation. For new-format bundles, the predicate type validation was bypassed completely. This vulnerability is fixed in 3.0.6 and 2.6.3.
CVE-2026-21007 2 Samsung, Samsung Mobile 3 Android, Mobile Devices, Samsung Mobile Devices 2026-04-15 6.8 Medium
Improper check for exceptional conditions in Device Care prior to SMR Apr-2026 Release 1 allows physical attackers to bypass Knox Guard.
CVE-2025-24303 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 7.8 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-23197 2026-04-15 6.5 Medium
matrix-hookshot is a Matrix bot for connecting to external services like GitHub, GitLab, JIRA, and more. When Hookshot 6 version 6.0.1 or below, or Hookshot 5 version 5.4.1 or below, is configured with GitHub support, it is vulnerable to a Denial of Service (DoS) whereby it can crash on restart due to a missing check. The impact is greater to you untrusted users can add their own GitHub organizations to Hookshot in order to connect their room to a repository. This vulnerability is fixed in 6.0.2 and 5.4.2.
CVE-2025-22848 2026-04-15 3.5 Low
Improper conditions check for some Edge Orchestrator software for Intel(R) Tiberâ„¢ Edge Platform may allow an authenticated user to potentially enable denial of service via adjacent access.
CVE-2025-20625 1 Intel 3 Proset, Proset/wireless, Proset/wireless Software 2026-04-15 7.4 High
Improper conditions check for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.110.0.5 may allow an unauthenticated user to potentially enable denial of service via adjacent access.
CVE-2025-20093 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 8.2 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-1718 2026-04-15 6.5 Medium
An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management.
CVE-2024-34360 2026-04-15 8.2 High
go-spacemesh is a Go implementation of the Spacemesh protocol full node. Nodes can publish activations transactions (ATXs) which reference the incorrect previous ATX of the Smesher that created the ATX. ATXs are expected to form a single chain from the newest to the first ATX ever published by an identity. Allowing Smeshers to reference an earlier (but not the latest) ATX as previous breaks this protocol rule and can serve as an attack vector where Nodes are rewarded for holding their PoST data for less than one epoch but still being eligible for rewards. This vulnerability is fixed in go-spacemesh 1.5.2-hotfix1 and Spacemesh API 1.37.1.
CVE-2024-10945 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 7.3 High
A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation.
CVE-2025-64342 1 Espressif 1 Esp-idf 2026-04-15 N/A
ESF-IDF is the Espressif Internet of Things (IOT) Development Framework. When the ESP32 is in advertising mode, if it receives a connection request containing an invalid Access Address (AA) of 0x00000000 or 0xFFFFFFFF, advertising may stop unexpectedly. In this case, the controller may incorrectly report a connection event to the host, which can cause the application layer to assume that the device has successfully established a connection. This issue has been fixed in versions 5.5.2, 5.4.3, 5.3.5, 5.2.6, and 5.1.7. At time of publication versions 5.5.2, 5.3.5, and 5.1.7 have not been released but are fixed respectively in commits 3b95b50, e3d7042, and 75967b5.
CVE-2025-61668 1 Plone 1 Volto 2026-04-15 N/A
Volto is a ReactJS-based frontend for the Plone Content Management System. Versions 16.34.0 and below, 17.0.0 through 17.22.1, 18.0.0 through 18.27.1, and 19.0.0-alpha.1 through 19.0.0-alpha.5, an anonymous user could cause the NodeJS server part of Volto to quit with an error when visiting a specific URL. This issue is fixed in versions 16.34.1, 17.22.2, 18.27.2 and 19.0.0-alpha.6.
CVE-2025-58354 1 Katacontainers 1 Kata-containers 2026-04-15 7.1 High
Kata Containers is an open source project focusing on a standard implementation of lightweight Virtual Machines (VMs) that perform like containers. In Kata Containers versions from 3.20.0 and before, a malicious host can circumvent initdata verification. On TDX systems running confidential guests, a malicious host can selectively fail IO operations to skip initdata verification. This allows an attacker to launch arbitrary workloads while being able to attest successfully to Trustee impersonating any benign workload. This issue has been patched in Kata Containers version 3.21.0.
CVE-2025-52136 1 Emqx 1 Emqx 2026-04-15 3 Low
In EMQX before 5.8.6, administrators can install arbitrary novel plugins via the Dashboard web interface. NOTE: the Supplier's position is that this is the intended behavior; however, 5.8.6 adds a defense-in-depth feature in which a plugin's acceptability (for later Dashboard installation) is set by the "emqx ctl plugins allow" CLI command.
CVE-2025-43715 1 Nullsoft 1 Nullsoft Scriptable Install System 2026-04-15 8.1 High
Nullsoft Scriptable Install System (NSIS) before 3.11 on Windows allows local users to escalate privileges to SYSTEM during an installation, because the temporary plugins directory is created under %WINDIR%\temp and unprivileged users can place a crafted executable file by winning a race condition. This occurs because EW_CREATEDIR does not always set the CreateRestrictedDirectory error flag.
CVE-2024-52504 1 Siemens 1 Siprotec 4 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
CVE-2024-2502 2026-04-15 2 Low
An application can be configured to block boot attempts after consecutive tamper resets are detected, which may not occur as expected. This is possible because the TAMPERRSTCAUSE register may not be properly updated when a level 4 tamper event (a tamper reset) occurs. This impacts Series 2 HSE-SVH devices, including xG23B, xG24B, xG25B, and xG28B, but does not impact xG21B. To mitigate this issue, upgrade to SE Firmware version 2.2.6 or later.
CVE-2024-27457 2026-04-15 2.5 Low
Improper check for unusual or exceptional conditions in Intel(R) TDX Module firmware before version 1.5.06 may allow a privileged user to potentially enable information disclosure via local access.
CVE-2024-34694 1 Lnbits 1 Lnbits 2026-04-15 8.1 High
LNbits is a Lightning wallet and accounts system. Paying invoices in Eclair that do not get settled within the internal timeout (about 30s) lead to a payment being considered failed, even though it may still be in flight. This vulnerability can lead to a total loss of funds for the node backend. This vulnerability is fixed in 0.12.6.
CVE-2025-53638 2026-04-15 N/A
Solady is software that provides Solidity snippets with APIs. Starting in version 0.0.125 and prior to version 0.1.24, when an account is deployed via a proxy, using regular Solidity to call its initialization function may result in a silent failure, if the initialization function does not return a `bool` or some other return data. This is because regular Solidity uses `extcodesize(proxy)` to decide if call succeeds. This is insufficient in the case when the proxy points to an empty implementation. Users should upgrade to Solady v0.1.24 or later to receive a patch. Deploy any affected implementations and their factories on new EVM chains as soon as possible.