| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In affected versions, vulnerability-lookup did not track or limit failed
One-Time Password (OTP) attempts during Two-Factor Authentication (2FA)
verification. An attacker who already knew or guessed a valid username
and password could submit an arbitrary number of OTP codes without
causing the account to be locked or generating any specific alert for
administrators.
This lack of rate-limiting and lockout on OTP failures significantly
lowers the cost of online brute-force attacks against 2FA codes and
increases the risk of successful account takeover, especially if OTP
entropy is reduced (e.g. short numeric codes, user reuse, or predictable
tokens). Additionally, administrators had no direct visibility into
accounts experiencing repeated 2FA failures, making targeted attacks
harder to detect and investigate.
The patch introduces a persistent failed_otp_attempts counter on user
accounts, locks the user after 5 invalid OTP submissions, resets the
counter on successful verification, and surfaces failed 2FA attempts in
the admin user list. This enforces an account lockout policy for OTP
brute-force attempts and improves monitoring capabilities for suspicious
2FA activity.This issue affects Vulnerability-Lookup: before 2.18.0. |
| The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application. |
| Due to missing authentication, SAP HANA 2.0 (hdbrss) allows an unauthenticated attacker to call a remote-enabled function that will enable them to view information. As a result, it has a low impact on the confidentiality but no impact on the integrity and availability of the system. |
| immich is a high performance self-hosted photo and video management solution. Prior to 1.132.0, immich is vulnerable to account hijacking through oauth2, because the state parameter is not being checked. The oauth2 state parameter is similar to a csrf token, so when the user starts the login flow this unpredictable token is generated and somehow saved in the browser session and passed to the identity provider, which will return the state parameter when redirecting the user back to immich. Before the user is logged in that parameter needs to be verified to make sure the login was actively initiated by the user in this browser session. On it's own, this wouldn't be too bad, but when immich uses the /user-settings page as a redirect_uri, it will automatically link the accounts if the user was already logged in. This means that if someone has an immich instance with a public oauth provider (like google), an attacker can - for example - embed a hidden iframe in a webpage or even just send the victim a forged oauth login url with a code that logs the victim into the attackers oauth account and redirects back to immich and links the accounts. After this, the attacker can log into the victims account using their own oauth credentials. This vulnerability is fixed in 1.132.0. |
| An unauthenticated user could discover account credentials via a brute-force attack without rate limiting |
| SEL BIOS packages prior to 1.3.49152.117 or 2.6.49152.98 allow a local attacker to bypass password authentication and change password-protected BIOS settings by importing a BIOS settings file with no password set. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| Pgpool-II provided by PgPool Global Development Group contains an authentication bypass by primary weakness vulnerability. if the vulnerability is exploited, an attacker may be able to log in to the system as an arbitrary user, allowing them to read or tamper with data in the database, and/or disable the database. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| An issue was discovered in Cicool builder 3.4.4 allowing attackers to reset the administrator's password via the /administrator/auth/reset_password endpoint. |
| The wallet has an authentication bypass vulnerability that allows access to specific pages. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |
| Nautobot Single Source of Truth (SSoT) is an app for Nautobot. Prior to version 3.10.0, an unauthenticated attacker could access this page to view the Service Now public instance name e.g. companyname.service-now.com. This is considered low-value information. This does not expose the Secret, the Secret Name, or the Secret Value for the Username/Password for Service-Now.com. An unauthenticated member would not be able to change the instance name, nor set a Secret. There is not a way to gain access to other pages Nautobot through the unauthenticated Configuration page. This issue has been patched in version 3.10.0. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |