| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. |
| Improper authentication handling was identified in a set of HTTP POST requests affecting the following product families:
* Digi PortServer TS - prior to and including 82000747_AA, build date 06/17/2022
* Digi One SP/Digi One SP IA/Digi One IA - prior to and including 82000774_Z, build date 10/19/2020
* Digi One IAP – prior to and including 82000770 Z, build date 10/19/2020
A specially crafted POST request to the device’s web interface may allow an unauthenticated attacker to modify configuration settings. |
| Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint. |
| The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a post request with new settings since there is no session token or authentication in place. This would allow an attacker for instance to point the device to an arbitrary address for domain name resolution to e.g. facililitate a man-in-the-middle (MitM) attack. |
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. |
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. |
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. |
| Token used for resetting passwords in MegaBIP software are generated using a small space of random values combined with a queryable value.
It allows an unauthenticated attacker who know user login names to brute force these tokens and change account passwords (including these belonging to administrators).
Version 5.20 of MegaBIP fixes this issue. |
| "This issue is limited to motherboards and does not affect laptops, desktop computers, or other endpoints." An insufficient validation vulnerability in ASUS DriverHub may allow untrusted sources to affect system behavior via crafted HTTP requests.
Refer to the 'Security Update for ASUS DriverHub' section on the ASUS Security Advisory for more information. |
| An Improper Resource Locking vulnerability in the SDM component of B&R Automation Runtime versions before 6.3 and before Q4.93 may allow an unauthenticated network-based attacker to delete data causing denial of service conditions. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| Web-Check is an all-in-one OSINT tool for analyzing any website. A command injection vulnerability exists in the screenshot API of the Web Check project (Lissy93/web-check). The issue stems from user-controlled input (url) being passed unsanitized into a shell command using exec(), allowing attackers to execute arbitrary system commands on the underlying host. This could be exploited by sending crafted url parameters to extract files or even establish remote access. The vulnerability has been patched by replacing exec() with execFile(), which avoids using a shell and properly isolates arguments. |
| A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server. |
| xrpl.js is a JavaScript/TypeScript API for interacting with the XRP Ledger in Node.js and the browser. Versions 4.2.1, 4.2.2, 4.2.3, and 4.2.4 of xrpl.js were compromised and contained malicious code designed to exfiltrate private keys. Version 2.14.2 is also malicious, though it is less likely to lead to exploitation as it is not compatible with other 2.x versions. Anyone who used one of these versions should stop immediately and rotate any private keys or secrets used with affected systems. Users of xrpl.js should pgrade to version 4.2.5 or 2.14.3 to receive a patch. To secure funds, think carefully about whether any keys may have been compromised by this supply chain attack, and mitigate by sending funds to secure wallets, and/or rotating keys. If any account's master key is potentially compromised, disable the key. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| An improper neutralization of inputs used in expression
language allows remote code execution with the highest privileges on the
server. |
| A path traversal vulnerability exists in multiple models of Selea Targa IP OCR-ANPR cameras, including iZero, Targa 512, Targa 504, Targa Semplice, Targa 704 TKM, Targa 805, Targa 710 INOX, Targa 750, and Targa 704 ILB. The /common/get_file.php script in the “Download Archive in Storage” page fails to properly validate user-supplied input to the file parameter. Unauthenticated remote attackers can exploit this vulnerability to read arbitrary files on the device, including sensitive system files containing cleartext credentials, potentially leading to authentication bypass and exposure of system information. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-02 UTC. |
| An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| An OS command injection vulnerability exists in various models of E-Series Linksys routers via the /tmUnblock.cgi and /hndUnblock.cgi endpoints over HTTP on port 8080. The CGI scripts improperly process user-supplied input passed to the ttcp_ip parameter without sanitization, allowing unauthenticated attackers to inject shell commands. This vulnerability was reported to be exploited in the wild by the "TheMoon" worm in 2014 to deploy a MIPS ELF payload, enabling arbitrary code execution on the router. Additionally, this vulnerability may affect other Linksys products to include, but not limited to, WAG/WAP/WES/WET/WRT-series router models and Wireless-N access points and routers. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-06 UTC. |