Export limit exceeded: 429120 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (5465 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-47891 | 2 Unified Intents, Unifiedremote | 2 Unified Remote, Unified Remote | 2026-04-15 | 9.8 Critical |
| Unified Remote 3.9.0.2463 contains a remote code execution vulnerability that allows attackers to send crafted network packets to execute arbitrary commands. Attackers can exploit the service by connecting to port 9512 and sending specially crafted packets to open a command prompt and download and execute malicious payloads. | ||||
| CVE-2025-44557 | 2026-04-15 | 8.1 High | ||
| A state machine transition flaw in the Bluetooth Low Energy (BLE) stack of Cypress PSoC4 v3.66 allows attackers to bypass the pairing process and authentication via a crafted pairing_failed packet. | ||||
| CVE-2024-9999 | 1 Progress Software | 1 Ws Ftp Server | 2026-04-15 | 6.5 Medium |
| In WS_FTP Server versions before 8.8.9 (2022.0.9), an Incorrect Implementation of Authentication Algorithm in the Web Transfer Module allows users to skip the second-factor verification and log in with username and password only. | ||||
| CVE-2025-9971 | 1 Planet | 1 Planet | 2026-04-15 | 9.8 Critical |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. | ||||
| CVE-2025-36756 | 1 Solax | 1 Solax Cloud | 2026-04-15 | N/A |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. | ||||
| CVE-2025-27214 | 2026-04-15 | 9.8 Critical | ||
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro (Version 1.5.18 and earlier) Mitigation: Update UniFi Connect EV Station Pro to Version 1.5.27 or later | ||||
| CVE-2025-34068 | 2026-04-15 | N/A | ||
| An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. | ||||
| CVE-2024-12511 | 2026-04-15 | 7.6 High | ||
| With address book access, SMB/FTP settings could be modified, redirecting scans and possibly capturing credentials. This requires enabled scan functions and printer access. | ||||
| CVE-2024-9928 | 1 Hitachienergy | 1 Nsd570 Firmware | 2026-04-15 | 5.3 Medium |
| A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second between failed login attempts making it difficult to automate the attacks. | ||||
| CVE-2025-58318 | 1 Delta Electronics | 1 Diaview | 2026-04-15 | N/A |
| Delta Electronics DIAView has an authentication bypass vulnerability. | ||||
| CVE-2025-34057 | 2026-04-15 | N/A | ||
| An information disclosure vulnerability exists in Ruijie NBR series routers (known to affect NBR2000G, NBR1300G, and NBR1000 models) via the /WEB_VMS/LEVEL15/ endpoint. By crafting a specific POST request with modified Cookie headers and specially formatted parameters, an unauthenticated attacker can retrieve administrative account credentials in plaintext. This flaw allows direct disclosure of sensitive user data due to improper authentication checks and insecure backend logic. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. | ||||
| CVE-2023-4857 | 2026-04-15 | 7.5 High | ||
| An authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information. | ||||
| CVE-2025-34089 | 2026-04-15 | N/A | ||
| An unauthenticated remote code execution vulnerability exists in Remote for Mac, a macOS remote control utility developed by Aexol Studio, in versions up to and including 2025.7. When the application is configured with authentication disabled (i.e., the "Allow unknown devices" option is enabled), the /api/executeScript endpoint is exposed without access control. This allows unauthenticated remote attackers to inject arbitrary AppleScript payloads via the X-Script HTTP header, resulting in code execution using do shell script. Successful exploitation grants attackers the ability to run arbitrary commands on the macOS host with the privileges of the Remote for Mac background process. | ||||
| CVE-2025-34039 | 1 Yonyou | 1 Ufida-nc | 2026-04-15 | N/A |
| A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. | ||||
| CVE-2025-34073 | 2026-04-15 | N/A | ||
| An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process. | ||||
| CVE-2023-48745 | 2026-04-15 | 5.3 Medium | ||
| Improper Restriction of Excessive Authentication Attempts vulnerability in WebFactory Ltd Captcha Code allows Functionality Bypass.This issue affects Captcha Code: from n/a through 2.9. | ||||
| CVE-2024-12371 | 2026-04-15 | N/A | ||
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. | ||||
| CVE-2015-10141 | 2026-04-15 | 5.6 Medium | ||
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. | ||||
| CVE-2024-9832 | 1 Baxter | 1 Life2000 Ventilator Firmware | 2026-04-15 | 9.3 Critical |
| There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure. | ||||
| CVE-2024-23815 | 1 Siemens | 1 Desigo Cc | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp) | ||||