| When configuring Arc (e.g. during the first setup), a local web interface is provided to ease the configuration process. Such web interface lacks authentication and may thus be abused by a local attacker or malware running on the machine itself.
A malicious local user or process, during a window of opportunity when the local web interface is active, may be able to extract sensitive information or change Arc's configuration. This could also lead to arbitrary code execution if a malicious update package is installed. |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP. |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP). |
| A unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via CAN. |
| Tinycontrol LAN Controller v3 (LK3) firmware versions up to 1.58a (hardware v3.8) contain a missing authentication vulnerability in the stm.cgi endpoint. A remote, unauthenticated attacker can send crafted requests to forcibly reboot the device or restore factory settings, leading to a denial of service and configuration loss. |
| Akka.NET is a .NET port of the Akka project from the Scala / Java community. In all versions of Akka.Remote from v1.2.0 to v1.5.51, TLS could be enabled via our `akka.remote.dot-netty.tcp` transport and this would correctly enforce private key validation on the server-side of inbound connections. Akka.Remote, however, never asked the outbound-connecting client to present ITS certificate - therefore it's possible for untrusted parties to connect to a private key'd Akka.NET cluster and begin communicating with it without any certificate. The issue here is that for certificate-based authentication to work properly, ensuring that all members of the Akka.Remote network are secured with the same private key, Akka.Remote needed to implement mutual TLS. This was not the case before Akka.NET v1.5.52. Those who run Akka.NET inside a private network that they fully control or who were never using TLS in the first place are now affected by the bug. However, those who use TLS to secure their networks must upgrade to Akka.NET V1.5.52 or later. One patch forces "fail fast" semantics if TLS is enabled but the private key is missing or invalid. Previous versions would only check that once connection attempts occurred. The second patch, a critical fix, enforces mutual TLS (mTLS) by default, so both parties must be keyed using the same certificate. As a workaround, avoid exposing the application publicly to avoid the vulnerability having a practical impact on one's application. However, upgrading to version 1.5.52 is still recommended by the maintainers. |
| An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Via port 7777 without any need to pair or press a physical button, a remote attacker can disable recording, delete recordings, or even disable battery protection to cause a flat battery to essentially disable the car from being used. During the process of changing these settings, there are no indications or sounds on the dashcam to alert the dashcam owner that someone else is making those changes. |
| Pgpool-II provided by PgPool Global Development Group contains an authentication bypass by primary weakness vulnerability. if the vulnerability is exploited, an attacker may be able to log in to the system as an arbitrary user, allowing them to read or tamper with data in the database, and/or disable the database. |
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can retrieve video stream images by directly accessing multiple image endpoints like middleImage.jpg, rightimage.jpg, and leftimage.jpg. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability in the ExportConfig REST API that allows attackers to download sensitive configuration files. Attackers can exploit the getConfigExportFile.cgi endpoint to retrieve system configurations, potentially enabling authentication bypass and privilege escalation. |
| FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication. |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| ZF Roll Stability Support Plus (RSSPlus)
is vulnerable to an authentication bypass vulnerability targeting
deterministic RSSPlus SecurityAccess service seeds, which may allow an
attacker to remotely (proximal/adjacent with RF equipment or via pivot
from J2497 telematics devices) call diagnostic functions intended for
workshop or repair scenarios. This can impact system availability,
potentially degrading performance or erasing software, however the
vehicle remains in a safe vehicle state. |
| The passwordless login mechanism in CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability, allowing remote attackers with regular privileges to send a crafted request to switch to the identity of any user, including administrators. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |