| A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| Aodh as packaged in Openstack Ocata and Newton before change-ID I8fd11a7f9fe3c0ea5f9843a89686ac06713b7851 and before Pike-rc1 does not verify that trust IDs belong to the user when creating alarm action with the scheme trust+http, which allows remote authenticated users with knowledge of trust IDs where Aodh is the trustee to obtain a Keystone token and perform unspecified authenticated actions by adding an alarm action with the scheme trust+http, and providing a trust id where Aodh is the trustee. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. |
| An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates. |
| firewalld.py in firewalld before 0.4.3.3 allows local users to bypass authentication and modify firewall configurations via the (1) addPassthrough, (2) removePassthrough, (3) addEntry, (4) removeEntry, or (5) setEntries D-Bus API method. |
| Two four letter word commands "wchp/wchc" are CPU intensive and could cause spike of CPU utilization on Apache ZooKeeper server if abused, which leads to the server unable to serve legitimate client requests. Apache ZooKeeper thru version 3.4.9 and 3.5.2 suffer from this issue, fixed in 3.4.10, 3.5.3, and later. |
| Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. |
| WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request. |
| A privilege escalation vulnerability in the Secure Shell (SSH) subsystem in the StarOS operating system for Cisco ASR 5000 Series, ASR 5500 Series, ASR 5700 Series devices, and Cisco Virtualized Packet Core could allow an authenticated, remote attacker to gain unrestricted, root shell access. The vulnerability is due to missing input validation of parameters passed during SSH or SFTP login. An attacker could exploit this vulnerability by providing crafted user input to the SSH or SFTP command-line interface (CLI) during SSH or SFTP login. An exploit could allow an authenticated attacker to gain root privileges access on the router. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability can be triggered via both IPv4 and IPv6 traffic. An established TCP connection toward port 22, the SSH default port, is needed to perform the attack. The attacker must have valid credentials to login to the system via SSH or SFTP. The following products have been confirmed to be vulnerable: Cisco ASR 5000/5500/5700 Series devices running StarOS after 17.7.0 and prior to 18.7.4, 19.5, and 20.2.3 with SSH configured are vulnerable. Cisco Virtualized Packet Core - Single Instance (VPC-SI) and Distributed Instance (VPC-DI) devices running StarOS prior to N4.2.7 (19.3.v7) and N4.7 (20.2.v0) with SSH configured are vulnerable. Cisco Bug IDs: CSCva65853. |
| VMware vCenter Server 5.5, 6.0, 6.5 allows vSphere users with certain, limited vSphere privileges to use the VIX API to access Guest Operating Systems without the need to authenticate. |
| IBM InfoSphere Master Data Management - Collaborative Edition 11.5 could allow an unauthorized user to download reports without authentication. IBM X-Force ID: 129892. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| Sony PCS-XG100, PCS-XG100S, PCS-XG100C, PCS-XG77, PCS-XG77S, PCS-XG77C devices with firmware versions prior to Ver.1.51 and PCS-XC1 devices with firmware version prior to Ver.1.22 allow an attacker on the same network segment to bypass authentication to perform administrative operations via unspecified vectors. |