| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Insufficiently protected credentials issue exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent unauthenticated attacker may obtain sensitive information such as a username and its password in the address book. |
| MENDELSON AS4 before 2024 B376 has a client-side vulnerability when a trading partner provides prepared XML data. When a victim opens the details of this transaction in the client, files can be written to the computer on which the client process is running. (The server process is not affected.) |
| A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the module define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified.
This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised. |
| A vulnerability classified as critical has been found in Byzoro Smart S80 Management Platform up to 20240411. Affected is an unknown function of the file /importhtml.php. The manipulation of the argument sql leads to deserialization. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| Unprotected Transport of Credentials vulnerability in OpenText™ Documentum™ Server could allow Credential Stuffing.This issue affects Documentum™ Server: from 16.7 through 23.4. |
| Team ENVY, a Security Research TEAM has found a flaw that allows for a remote code execution on the NVR. The seed string for the encrypt key was hardcoding. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds. |
| Insertion of Sensitive Information into Log File (CWE-532) in the Gallagher Command Centre Alarm Transmitter feature could allow an authenticated Operator to view some security sensitive information to which they have not been granted access.
This issue affects: Command Centre Server 9.10 prior to 9.10.2149 (MR4), 9.00 prior to 9.00.2374 (MR5), 8.90 prior to 8.90.2356 (MR6), all versions of 8.80 and prior. |
| Passwords of agents and customers are displayed in plain text in the OTRS admin log module if certain configurations regarding the authentication sources match and debugging for the authentication backend has been enabled.
This issue affects:
* OTRS from 7.0.X through 7.0.50
* OTRS 8.0.X
* OTRS 2023.X
* OTRS from 2024.X through 2024.5.X
* ((OTRS)) Community Edition: 6.0.x
Products based on the ((OTRS)) Community Edition also very likely to be affected |
| Insertion of Sensitive Information into Log File vulnerability in StylemixThemes Masterstudy LMS Starter.This issue affects Masterstudy LMS Starter: from n/a through 1.1.8. |
| The ShiftController Employee Shift Scheduling plugin is vulnerable to PHP Object Injection via deserialization of untrusted input via the `hc3_session`-cookie in versions up to, and including, 4.9.57. This makes it possible for an authenticated attacker with contributor access-level or above to inject a PHP Object. No POP chain is present in the vulnerable plugin. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code. |
| Improper error handling in firmware of some SSD DC Products may allow an attacker to enable denial of service. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices. |
| NovaCHRON Zeitsysteme GmbH & Co. KG Smart Time Plus v8.x to v8.6 was discovered to contain a SQL injection vulnerability via the getCookieNames method in the smarttimeplus/MySQLConnection endpoint. |
| AshPostgres is the PostgreSQL data layer for Ash Framework. Starting in version 2.0.0 and prior to version 2.4.10, in certain very specific situations, it was possible for the policies of an update action to be skipped. This occurred only on "empty" update actions (no changing fields), and would allow their hooks (side effects) to be performed when they should not have been. Note that this does not allow reading new data that the user should not have had access to, only triggering a side effect a user should not have been able to trigger.
To be vulnerable, an affected user must have an update action that is on a resource with no attributes containing an "update default" (updated_at timestamp, for example); can be performed atomically; does not have `require_atomic? false`; has at least one authorizer (typically `Ash.Policy.Authorizer`); and has at least one `change` (on the resource's `changes` block or in the action itself). This is where the side-effects would be performed when they should not have been.
This problem has been patched in `2.4.10` of `ash_postgres`. Several workarounds are available. Potentially affected users may determine that none of their actions are vulnerable using a script the maintainers provide in the GitHub Security Advisory, add `require_atomic? false` to any potentially affected update action, replace any usage of `Ash.update` with `Ash.bulk_update` for an affected action, and/or add an update timestamp to their action. |
| Ubee EVW3226 cable modem/routers firmware versions up to and including 1.0.20 store configuration backup files in the web root after they are generated for download. These backup files remain accessible without authentication until the next reboot. A remote attacker on the local network can request 'Configuration_file.cfg' directly to obtain the backup archive. Because backup files are not encrypted, they expose sensitive information including the plaintext admin password, allowing full compromise of the device. |
| A remote code execution vulnerability exists in Kaltura versions prior to 11.1.0-2 due to unsafe deserialization of user-controlled data within the keditorservices module. An unauthenticated remote attacker can exploit this issue by sending a specially crafted serialized PHP object in the kdata GET parameter to the redirectWidgetCmd endpoint. Successful exploitation leads to execution of arbitrary PHP code in the context of the web server process. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| An issue in the luci-mod-rpc package in OpenWRT Luci LTS allows for privilege escalation from an admin account to root via the JSON-RPC-API, which is exposed by the luci-mod-rpc package |
| AnyDesk through 8.1.0 on Windows, when Allow Direct Connections is enabled, inadvertently exposes a public IP address within network traffic. The attacker must know the victim's AnyDesk ID. |
| Insecure deserialization in Hodoku v2.3.0 to v2.3.2 allows attackers to execute arbitrary code. |