Search Results (1455 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-20093 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 8.2 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-24303 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 7.8 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-27408 2026-04-15 4.8 Medium
Manifest offers users a one-file micro back end. Prior to version 4.9.2, Manifest employs a weak password hashing implementation that uses SHA3 without a salt. This exposes user passwords to a higher risk of being cracked if an attacker gains access to the database. Without the use of a salt, identical passwords across multiple users will result in the same hash, making it easier for attackers to identify and exploit patterns, thereby accelerating the cracking process. Version 4.9.2 fixes the issue.
CVE-2025-53638 2026-04-15 N/A
Solady is software that provides Solidity snippets with APIs. Starting in version 0.0.125 and prior to version 0.1.24, when an account is deployed via a proxy, using regular Solidity to call its initialization function may result in a silent failure, if the initialization function does not return a `bool` or some other return data. This is because regular Solidity uses `extcodesize(proxy)` to decide if call succeeds. This is insufficient in the case when the proxy points to an empty implementation. Users should upgrade to Solady v0.1.24 or later to receive a patch. Deploy any affected implementations and their factories on new EVM chains as soon as possible.
CVE-2025-54427 1 Polkadot 1 Frontier 2026-04-15 N/A
Polkadot Frontier is an Ethereum and EVM compatibility layer for Polkadot and Substrate. The extrinsic note_min_gas_price_target is an inherent extrinsic, meaning only the block producer can call it. To ensure correctness, the ProvideInherent trait should be implemented for each inherent, which includes the check_inherent call. This allows other nodes to verify if the input (in this case, the target value) is correct. However, prior to commit a754b3d, the check_inherent function has not been implemented for note_min_gas_price_target. This lets the block producer set the target value without verification. The target is then used to set the MinGasPrice, which has an upper and lower bound defined in the on_initialize hook. The block producer can set the target to the upper bound. Which also increases the upper and lower bounds for the next block. Over time, this could result in continuously raising the gas price, making contract execution too expensive and ineffective for users. An attacker could use this flaw to manipulate the gas price, potentially leading to significantly inflated transaction fees. Such manipulation could render contract execution prohibitively expensive for users, effectively resulting in a denial-of-service condition for the network. This is fixed in version a754b3d.
CVE-2025-54811 1 Openplcproject 2 Openplc V3, Openplc V3 Firmware 2026-04-15 7.1 High
OpenPLC_V3 has a vulnerability in the enipThread function that occurs due to the lack of a return value. This leads to a crash when the server loop ends and execution hits an illegal ud2 instruction. This issue can be triggered remotely without authentication by starting the same server multiple times or if the server exits unexpectedly. The vulnerability allows an attacker to cause a Denial of Service (DoS) against the PLC runtime, stopping any PC started remotely without authentication. This results in the PLC process crashing and halting all automation or control logic managed by OpenPLC.
CVE-2025-61668 1 Plone 1 Volto 2026-04-15 N/A
Volto is a ReactJS-based frontend for the Plone Content Management System. Versions 16.34.0 and below, 17.0.0 through 17.22.1, 18.0.0 through 18.27.1, and 19.0.0-alpha.1 through 19.0.0-alpha.5, an anonymous user could cause the NodeJS server part of Volto to quit with an error when visiting a specific URL. This issue is fixed in versions 16.34.1, 17.22.2, 18.27.2 and 19.0.0-alpha.6.
CVE-2025-9437 1 Rockwellautomation 1 Armorstart Aop 2026-04-15 N/A
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.
CVE-2025-9998 1 Arcinfo 1 Pcvue 2026-04-15 N/A
The sequence of packets received by a Networking server are not correctly checked. An attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.
CVE-2025-52136 1 Emqx 1 Emqx 2026-04-15 3 Low
In EMQX before 5.8.6, administrators can install arbitrary novel plugins via the Dashboard web interface. NOTE: the Supplier's position is that this is the intended behavior; however, 5.8.6 adds a defense-in-depth feature in which a plugin's acceptability (for later Dashboard installation) is set by the "emqx ctl plugins allow" CLI command.
CVE-2025-10205 1 Abb 1 Flxeon 2026-04-15 8.8 High
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions
CVE-2024-21806 2026-04-15 5.5 Medium
Improper conditions check in Linux kernel mode driver for some Intel(R) Ethernet Network Controllers and Adapters E810 Series before version 28.3 may allow an authenticated user to potentially enable denial of service via local access.
CVE-2024-23079 2026-04-15 6.2 Medium
JGraphT Core v1.5.2 was discovered to contain a NullPointerException via the component org.jgrapht.alg.util.ToleranceDoubleComparator::compare(Double, Double). NOTE: this is disputed by multiple third parties who believe there was not reasonable evidence to determine the existence of a vulnerability. The submission may have been based on a tool that is not sufficiently robust for vulnerability identification.
CVE-2025-20070 1 Intel 1 Intel Optane Pmem Management Software 2026-04-15 6.7 Medium
Improper conditions check for the Intel(R) Optane(TM) PMem management software before versions CR_MGMT_02.00.00.4052, CR_MGMT_03.00.00.0538 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable [cvss_threat_loss_factor]. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-1718 2026-04-15 6.5 Medium
An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management.
CVE-2024-27457 2026-04-15 2.5 Low
Improper check for unusual or exceptional conditions in Intel(R) TDX Module firmware before version 1.5.06 may allow a privileged user to potentially enable information disclosure via local access.
CVE-2025-23197 2026-04-15 6.5 Medium
matrix-hookshot is a Matrix bot for connecting to external services like GitHub, GitLab, JIRA, and more. When Hookshot 6 version 6.0.1 or below, or Hookshot 5 version 5.4.1 or below, is configured with GitHub support, it is vulnerable to a Denial of Service (DoS) whereby it can crash on restart due to a missing check. The impact is greater to you untrusted users can add their own GitHub organizations to Hookshot in order to connect their room to a repository. This vulnerability is fixed in 6.0.2 and 5.4.2.
CVE-2025-24478 2026-04-15 N/A
A denial-of-service vulnerability exists in the affected products. The vulnerability could allow a remote, non-privileged user to send malicious requests resulting in a major nonrecoverable fault causing a denial-of-service.
CVE-2024-28036 2026-04-15 5.6 Medium
Improper conditions check for some Intel(R) Arc™ GPU may allow an authenticated user to potentially enable denial of service via local access.
CVE-2025-41222 2026-04-15 5.3 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). Affected devices do not properly handle malformed TLS handshake messages. This could allow an attacker with network access to the webserver to cause a denial of service resulting in the web server and the device to crash.