| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| VMware vCenter Server (6.5 prior to 6.5 U1) contains an information disclosure vulnerability. This issue may allow plaintext credentials to be obtained when using the vCenter Server Appliance file-based backup feature. |
| An issue was discovered in these Pivotal RabbitMQ versions: all 3.4.x versions, all 3.5.x versions, and 3.6.x versions prior to 3.6.9; and these RabbitMQ for PCF versions: all 1.5.x versions, 1.6.x versions prior to 1.6.18, and 1.7.x versions prior to 1.7.15. RabbitMQ management UI stores signed-in user credentials in a browser's local storage without expiration, making it possible to retrieve them using a chained attack. |
| Insufficient protection of password storage in system firmware for Intel NUC7i3BNK, NUC7i3BNH, NUC7i5BNK, NUC7i5BNH, NUC7i7BNH versions BN0049 and below allows local attackers to bypass Administrator and User passwords via access to password storage. |
| The PSFTPd 10.0.4 Build 729 server stores its configuration inside PSFTPd.dat. This file is a Microsoft Access Database and can be extracted. The application sets the encrypt flag with the password "ITsILLEGAL"; however, this password is not required to extract the data. Cleartext is used for a user password. |
| A design flaw in authentication in Synology Photo Station 6.0-2528 through 6.7.1-3419 allows local users to obtain credentials via cmdline. Synology Photo Station employs the synophoto_dsm_user program to authenticate username and password by "synophoto_dsm_user --auth USERNAME PASSWORD", and local users are able to obtain credentials by sniffing "/proc/*/cmdline". |
| register.ghp in EFS Software Easy Chat Server versions 2.0 to 3.1 allows remote attackers to discover passwords by sending the username parameter in conjunction with an empty password parameter, and reading the HTML source code of the response. |
| The D-Link NPAPI extension, as used in conjunction with D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices, sends the cleartext admin password over the Internet as part of interaction with mydlink Cloud Services. |
| IBM Security Identity Manager Adapters 6.0 and 7.0 stores user credentials in plain in clear text which can be read by a local user. IBM X-Force ID: 126801. |
| A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. |
| An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks. |
| Pentaminds CuroVMS v2.0.1 was discovered to contain exposed credentials. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure. |
| The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently. |
| An attacker with physical access to the host can extract the secrets from the registry and create valid JWT tokens for the Fresenius Kabi Vigilant MasterMed version 2.0.1.3 application and impersonate arbitrary users. An attacker could manipulate RabbitMQ queues and messages by impersonating users. |
| Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval. |
| The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. |
| A malicious actor having access to the exported configuration file may obtain the stored credentials and thereby gain access to the protected resource. If the same passwords were used for other resources, further such assets may be compromised. |
| An attacker with weak credentials could access the TCP port via an open FTP port, allowing an attacker to read sensitive files and write to remotely executable directories. |
| The default password for the web application’s root user (the vendor’s private account) was weak and the MD5 hash was used to crack the password using a widely available open-source tool. |
| An information disclosure vulnerability exists in the License registration functionality of Bachmann Visutec GmbH Atvise 3.5.4, 3.6 and 3.7. A plaintext HTTP request can lead to a disclosure of login credentials. An attacker can perform a man-in-the-middle attack to trigger this vulnerability. |