| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An authenticated administrator could cause the server to issue requests to, and interact with, internal network services that are not meant to be reachable through this interface. On its own this did not result in code execution. |
| An authenticated Email Protection Gateway administrator holding only limited, delegated permissions could write files with attacker-controlled content to arbitrary locations accessible to the Email Protection Gateway service account. This exceeds the administrator's intended privileges and could be used to alter application files and configuration or to disrupt the availability of the service. |
| A security vulnerability has been detected in jbardin scp.py up to 0.16.1. The impacted element is the function _recv_file/_recv_pushd of the component SCP Receive Handler. The manipulation leads to path traversal. Remote exploitation of the attack is possible. Upgrading to version 0.16.2 is sufficient to resolve this issue. The identifier of the patch is 42fc3aaa71411daed60544e3b40179c1038bed5d. Upgrading the affected component is advised. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product. |
| A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access. |
| Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization. |
| A vulnerability was detected in MosaicML Composer up to 0.32.1. This affects the function tarball.extractall of the file composer/utils/checkpoint.py of the component Checkpoint Extraction. The manipulation results in path traversal. The attack can be executed remotely. The vendor was contacted early about this disclosure. |
| A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| Rill 0.77.0 through 0.90.5 contains a missing authorization vulnerability in the admin OAuth server that issues authorization codes to dynamically registered clients without user consent. Attackers can register a client with the long_lived_access_token scope and lure a user to an authorization link, obtaining a non-expiring API token with the user's full permissions. |
| answer-me-with-html through 0.5.0 contains a link following vulnerability in the am CLI code block src= embedding, where localPath() checks only path text without resolving symlinks. Attackers can ship a repository with a symlink pointing outside the checkout so am render embeds readable external files into generated HTML, disclosing them when shared. |
| Flyte 2.0.1 through 2.0.51 contains a cleartext secret storage vulnerability that allows users with Pod read access to obtain secrets by reading init container environment variables. The embedded secret manager webhook writes base64-encoded FILE-mounted secret values into the SECRETS environment variable, letting principals without Secret store access decode them from the Pod spec. |
| pbi-cli 3.10.1 through 3.12.0 contains an OS command injection vulnerability in desktop_sync.py that passes unquoted .pbip paths to cmd /c start when reopening projects. Attackers can lure victims into opening a Power BI project from a space-free path containing & to run commands with victim privileges during report write or reload. |
| Quarkus LangChain4j 1.9.0 through 1.14.1 contains a missing release of memory vulnerability in the chat-scopes WebSocket /_chat/routes endpoint that allows unauthenticated remote clients to exhaust server memory. Attackers can send repeated CONNECT frames reusing one chatId, leaving orphaned scopes in activeScopes until the JVM exits and degrading availability. |
| GPT-Load through 1.4.11 contains a cleartext logging vulnerability that exposes client proxy keys because the Gin Logger middleware records the raw query string before extractAuthKey strips the key parameter. Attackers with read access to console logs or ./data/logs/app.log can recover proxy keys from Gemini-style requests and use them against the corresponding group. |