| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Execution with Unnecessary Privileges vulnerability in the User Interface (UI) of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privileged attacker to gain root privileges, thus compromising the system.
When a configuration that allows unsigned Python op scripts is present on the device, a non-root user is able to execute malicious op scripts as a root-equivalent user, leading to privilege escalation.
This issue affects Junos OS:
* All versions before 22.4R3-S7,
* from 23.2 before 23.2R2-S4,
* from 23.4 before 23.4R2-S6,
* from 24.2 before 24.2R1-S2, 24.2R2,
* from 24.4 before 24.4R1-S2, 24.4R2;
Junos OS Evolved:
* All versions before 22.4R3-S7-EVO,
* from 23.2 before 23.2R2-S4-EVO,
* from 23.4 before 23.4R2-S6-EVO,
* from 24.2 before 24.2R2-EVO,
* from 24.4 before 24.4R1-S1-EVO, 24.4R2-EVO. |
| bleon-ethical/api-gateway-deploy provides API gateway deployment. Version 1.0.0 is vulnerable to an attack chain involving OS Command Injection and Privilege Escalation. This allows an attacker to execute arbitrary commands with root privileges within the container, potentially leading to a container escape and unauthorized infrastructure modifications. This is fixed in version 1.0.1 by implementing strict input sanitization and secure delimiters in entrypoint.sh, enforcing a non-root user (appuser) in the Dockerfile, and establishing mandatory security quality gates. |
| theshit is a command-line utility that automatically detects and fixes common mistakes in shell commands. Prior to version 0.2.0, improper privilege dropping allows local privilege escalation via command re-execution. This issue has been patched in version 0.2.0. |
| Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an execution with unnecessary privileges vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to denial of service, elevation of privileges, and information disclosure. |
| Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an execution with unnecessary privileges vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to elevation of privileges. |
| Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an execution with unnecessary privileges vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges. |
| OliveTin gives access to predefined shell commands from a web interface. Prior to version 3000.11.1, an authentication context confusion vulnerability in RestartAction allows a low‑privileged authenticated user to execute actions they are not permitted to run. RestartAction constructs a new internal connect.Request without preserving the original caller’s authentication headers or cookies. When this synthetic request is passed to StartAction, the authentication resolver falls back to the guest user. If the guest account has broader permissions than the authenticated caller, this results in privilege escalation and unauthorized command execution. This vulnerability allows a low‑privileged authenticated user to bypass ACL restrictions and execute arbitrary configured shell actions. This issue has been patched in version 3000.11.1. |
| The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed. |
| In BootRom, there is a possible unchecked write address. This could lead to local escalation of privilege with no additional execution privileges needed. |
| In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems. |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. |
| The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future. |
| The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |
| Attackers with local access to the medical office computer can
escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by
overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is
writable for all users. In addition, the Elefant installer registers two
Firebird database services which are running as “NT AUTHORITY\SYSTEM”.
Path: C:\Elefant1\Firebird_2\bin\fbserver.exe
Path: C:\Elefant1\Firebird_2\bin\fbguard.exe
Both service binaries are user writable. This means that a local
attacker can rename one of the service binaries, replace the service
executable with a new executable, and then restart the system. Once the
system has rebooted, the new service binary is executed as "NT
AUTHORITY\SYSTEM". |