Export limit exceeded: 16732 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (16732 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-24313 | 2 Intel, Kubernetes | 2 Device Plugins For Kubernetes, Kubernetes | 2026-04-15 | 4.4 Medium |
| Improper access control for some Device Plugins for Kubernetes software maintained by Intel before version 0.32.0 may allow a privileged user to potentially enable denial of service via local access. | ||||
| CVE-2025-24292 | 1 Ubiquiti | 1 Unifi Network Application | 2026-04-15 | N/A |
| A misconfigured query in UniFi Network (v9.1.120 and earlier) could allow users to authenticate to Enterprise WiFi or VPN Server (l2tp and OpenVPN) using a device’s MAC address from 802.1X or MAC Authentication, if both services are enabled and share the same RADIUS profile. | ||||
| CVE-2025-23217 | 1 Mitmproxy | 1 Mitmproxy | 2026-04-15 | N/A |
| mitmproxy is a interactive TLS-capable intercepting HTTP proxy for penetration testers and software developers and mitmweb is a web-based interface for mitmproxy. In mitmweb 11.1.1 and below, a malicious client can use mitmweb's proxy server (bound to `*:8080` by default) to access mitmweb's internal API (bound to `127.0.0.1:8081` by default). In other words, while the cannot access the API directly, they can access the API through the proxy. An attacker may be able to escalate this SSRF-style access to remote code execution. The mitmproxy and mitmdump tools are unaffected. Only mitmweb is affected. This vulnerability has been fixed in mitmproxy 11.1.2 and above. Users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||
| CVE-2025-23203 | 2026-04-15 | 5.5 Medium | ||
| Icinga Director is an Icinga config deployment tool. A Security vulnerability has been found starting in version 1.0.0 and prior to 1.10.4 and 1.11.4 on several director endpoints of REST API. To reproduce this vulnerability an authenticated user with permission to access the Director is required (plus api access with regard to the api endpoints). And even though some of these Icinga Director users are restricted from accessing certain objects, are able to retrieve information related to them if their name is known. This makes it possible to change the configuration of these objects by those Icinga Director users restricted from accessing them. This results in further exploitation, data breaches and sensitive information disclosure. Affected endpoints include icingaweb2/director/service, if the host name is left out of the query; icingaweb2/directore/notification; icingaweb2/director/serviceset; and icingaweb2/director/scheduled-downtime. In addition, the endpoint `icingaweb2/director/services?host=filteredHostName` returns a status code 200 even though the services for the host is filtered. This in turn lets the restricted user know that the host `filteredHostName` exists even though the user is restricted from accessing it. This could again result in further exploitation of this information and data breaches. Icinga Director has patches in versions 1.10.4 and 1.11.4. If upgrading is not feasible, disable the director module for the users other than admin role for the time being. | ||||
| CVE-2025-23164 | 2026-04-15 | N/A | ||
| A misconfigured access token mechanism in the Unifi Protect Application (Version 5.3.41 and earlier) could permit the recipient of a "Share Livestream" link to maintain access to the corresponding livestream subsequent to such link becoming disabled. | ||||
| CVE-2025-23116 | 2026-04-15 | N/A | ||
| An Authentication Bypass vulnerability on UniFi Protect Application with Auto-Adopt Bridge Devices enabled could allow a malicious actor with access to UniFi Protect Cameras adjacent network to take control of UniFi Protect Cameras. | ||||
| CVE-2025-23083 | 1 Redhat | 2 Enterprise Linux, Rhel Eus | 2026-04-15 | N/A |
| With the aid of the diagnostics_channel utility, an event can be hooked into whenever a worker thread is created. This is not limited only to workers but also exposes internal workers, where an instance of them can be fetched, and its constructor can be grabbed and reinstated for malicious usage. This vulnerability affects Permission Model users (--permission) on Node.js v20, v22, and v23. | ||||
| CVE-2025-2306 | 2026-04-15 | 5.9 Medium | ||
| An Improper Access Control vulnerability was identified in the file download functionality. This vulnerability allows users to download sensitive documents without authentication, if the URL is known. The attack requires the attacker to know the documents UUIDv4. | ||||
| CVE-2025-22391 | 1 Intel | 1 Sigtest | 2026-04-15 | 6.7 Medium |
| Improper access control for some SigTest before version 6.1.10 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. | ||||
| CVE-2022-4001 | 1 Motorola | 1 Q14 Mesh Router Firmware | 2026-04-15 | 7.3 High |
| An authentication bypass vulnerability could allow an attacker to access API functions without authentication. | ||||
| CVE-2025-22375 | 2026-04-15 | N/A | ||
| An authentication bypass vulnerability was found in Videx's CyberAudit-Web. Through the exploitation of a logic flaw, an attacker could create a valid session without any credentials. This vulnerability has been patched in versions later than 9.5 and a patch has been made available to all instances of CyberAudit-Web, including the versions that are End of Maintenance (EOM). Anyone that requires support with the resolution of this issue can contact support@videx.com for assistance. | ||||
| CVE-2025-20099 | 1 Intel | 1 Rapid Storage Technology | 2026-04-15 | 6.7 Medium |
| Improper access control for some Intel(R) Rapid Storage Technology installation software may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2022-43110 | 1 Voltronicpower | 1 Viewpower | 2026-04-15 | 9.8 Critical |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. | ||||
| CVE-2025-20076 | 2026-04-15 | 5 Medium | ||
| Improper access control for some Edge Orchestrator software for Intel(R) Tiber™ Edge Platform may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access. | ||||
| CVE-2025-15586 | 1 Opengamepanel | 1 Ogp-website | 2026-04-15 | N/A |
| OGP-Website installs prior git commit 52f865a4fba763594453068acf8fa9e3fc38d663 are affected by a type juggling flaw which if exploited can result in authentication bypass without knowledge of the victim account's password. | ||||
| CVE-2025-15097 | 1 Alteryx | 1 Alteryx Server | 2026-04-15 | 7.3 High |
| A vulnerability was found in Alteryx Server. Affected by this issue is some unknown functionality of the file /gallery/api/status/. Performing manipulation results in improper authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. Upgrading to version 2023.1.1.13.486, 2023.2.1.10.293, 2024.1.1.9.236, 2024.2.1.6.125 and 2025.1.1.1.31 can resolve this issue. Upgrading the affected component is recommended. | ||||
| CVE-2022-45929 | 1 Northern.tech | 1 Mender | 2026-04-15 | 8.8 High |
| Northern.tech Mender 3.3.x before 3.3.2, 3.5.x before 3.5.0, and 3.6.x before 3.6.0 has Incorrect Access Control and allows users to change their roles and could allow privilege escalation from a low-privileged read-only user to a high-privileged user. | ||||
| CVE-2025-10741 | 1 Selleo | 1 Mentingo | 2026-04-15 | 6.3 Medium |
| A security vulnerability has been detected in Selleo Mentingo up to 2025.08.27. The affected element is an unknown function of the component Profile Picture Handler. The manipulation of the argument userAvatar leads to unrestricted upload. The attack is possible to be carried out remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-14777 | 1 Redhat | 1 Build Keycloak | 2026-04-15 | 6 Medium |
| A flaw was found in Keycloak. An IDOR (Broken Access Control) vulnerability exists in the admin API endpoints for authorization resource management, specifically in ResourceSetService and PermissionTicketService. The system checks authorization against the resourceServer (client) ID provided in the API request, but the backend database lookup and modification operations (findById, delete) only use the resourceId. This mismatch allows an authenticated attacker with fine-grained admin permissions for one client (e.g., Client A) to delete or update resources belonging to another client (Client B) within the same realm by supplying a valid resource ID. | ||||
| CVE-2022-47036 | 1 Siklu | 1 Tg Terragraph | 2026-04-15 | 9.8 Critical |
| Siklu TG Terragraph devices before approximately 2.1.1 have a hardcoded root password that has been revealed via a brute force attack on an MD5 hash. It can be used for "debug login" by an admin. NOTE: the vulnerability is not fixed by the 2.1.1 firmware; instead, it is fixed in newer hardware, which would typically be used with firmware 2.1.1 or later. | ||||