Export limit exceeded: 422056 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 109511 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (109511 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-22092 | 1 Openatom | 1 Openharmony | 2025-01-27 | 7.7 High |
| in OpenHarmony v3.2.4 and prior versions allow a remote attacker bypass permission verification to install apps, although these require user action. | ||||
| CVE-2023-31531 | 1 Motorola | 2 Cx2l, Cx2l Firmware | 2025-01-27 | 8.8 High |
| Motorola CX2L Router 1.0.1 was discovered to contain a command injection vulnerability via the tomography_ping_number parameter. | ||||
| CVE-2023-31530 | 1 Motorola | 2 Cx2l, Cx2l Firmware | 2025-01-27 | 8.8 High |
| Motorola CX2L Router 1.0.1 was discovered to contain a command injection vulnerability via the smartqos_priority_devices parameter. | ||||
| CVE-2023-31529 | 1 Motorola | 2 Cx2l, Cx2l Firmware | 2025-01-27 | 8.8 High |
| Motorola CX2L Router 1.0.1 was discovered to contain a command injection vulnerability via the system_time_timezone parameter. | ||||
| CVE-2023-31528 | 1 Motorola | 2 Cx2l, Cx2l Firmware | 2025-01-27 | 8.8 High |
| Motorola CX2L Router 1.0.1 was discovered to contain a command injection vulnerability via the staticroute_list parameter. | ||||
| CVE-2023-31442 | 1 Lightbend | 2 Akka Actor, Akka Discovery | 2025-01-27 | 7.5 High |
| In Lightbend Akka before 2.8.1, the async-dns resolver (used by Discovery in DNS mode and transitively by Cluster Bootstrap) uses predictable DNS transaction IDs when resolving DNS records, making DNS resolution subject to poisoning by an attacker. If the application performing discovery does not validate (e.g., via TLS) the authenticity of the discovered service, this may result in exfiltration of application data (e.g., persistence events may be published to an unintended Kafka broker). If such validation is performed, then the poisoning constitutes a denial of access to the intended service. This affects Akka 2.5.14 through 2.8.0, and Akka Discovery through 2.8.0. | ||||
| CVE-2023-30765 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-27 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation. | ||||
| CVE-2023-30172 | 1 Lfprojects | 1 Mlflow | 2025-01-27 | 7.5 High |
| A directory traversal vulnerability in the /get-artifact API method of the mlflow platform up to v2.0.1 allows attackers to read arbitrary files on the server via the path parameter. | ||||
| CVE-2023-28356 | 1 Rocket.chat | 1 Rocket.chat | 2025-01-27 | 7.5 High |
| A vulnerability has been identified where a maliciously crafted message containing a specific chain of characters can cause the chat to enter a hot loop on one of the processes, consuming ~120% CPU and rendering the service unresponsive. | ||||
| CVE-2021-34076 | 1 Phpok | 1 Phpok | 2025-01-27 | 8.8 High |
| File Upload vulnerability in PHPOK 5.7.140 allows remote attackers to run arbitrary code and gain escalated privileges via crafted zip file upload. | ||||
| CVE-2024-2547 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-2558 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4114 | 1 Tenda | 2 Tx9 Pro, Tx9 Pro Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4111 | 1 Tenda | 2 Tx9 Pro, Tx9 Pro Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4112 | 1 Tenda | 2 Tx9 Pro, Tx9 Pro Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-3881 | 1 Tenda | 2 W30e, W30e Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-3882 | 1 Tenda | 2 W30e, W30e Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-3879 | 1 Tenda | 2 W30e, W30e Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2023-37029 | 1 Linuxfoundation | 1 Magma | 2025-01-27 | 7.5 High |
| Magma versions <= 1.8.0 (fixed in v1.9 commit 08472ba98b8321f802e95f5622fa90fec2dea486) are susceptible to an assertion-based crash when an oversized NAS packet is received. An attacker may leverage this behavior to repeatedly crash the MME via either a compromised base station or via an unauthenticated cellphone within range of a base station managed by the MME, causing a denial of service. | ||||
| CVE-2023-2444 | 1 Rockwellautomation | 1 Factorytalk Vantagepoint | 2025-01-24 | 7.1 High |
| A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product. Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well. | ||||