Export limit exceeded: 107873 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (107873 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-24419 | 1 Dell | 92 Alienware 13 R3, Alienware 13 R3 Firmware, Alienware 15 R3 and 89 more | 2024-11-21 | 8.2 High |
| Dell BIOS contains an improper input validation vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to gain arbitrary code execution during SMM. | ||||
| CVE-2022-24418 | 1 Dell | 56 Dell G5 5505, Dell G5 5505 Firmware, Inspiron 22-3275 and 53 more | 2024-11-21 | 7.5 High |
| Dell BIOS contains an improper input validation vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to gain arbitrary code execution during SMM. | ||||
| CVE-2022-24417 | 1 Dell | 56 Dell G5 5505, Dell G5 5505 Firmware, Inspiron 22-3275 and 53 more | 2024-11-21 | 7.5 High |
| Dell BIOS contains an improper input validation vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to gain arbitrary code execution during SMM. | ||||
| CVE-2022-24416 | 1 Dell | 92 Alienware 13 R3, Alienware 13 R3 Firmware, Alienware 15 R3 and 89 more | 2024-11-21 | 8.2 High |
| Dell BIOS contains an improper input validation vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to gain arbitrary code execution during SMM. | ||||
| CVE-2022-24415 | 1 Dell | 92 Alienware 13 R3, Alienware 13 R3 Firmware, Alienware 15 R3 and 89 more | 2024-11-21 | 8.2 High |
| Dell BIOS contains an improper input validation vulnerability. A local authenticated malicious user may potentially exploit this vulnerability by using an SMI to gain arbitrary code execution during SMM. | ||||
| CVE-2022-24414 | 1 Dell | 1 Cloudlink | 2024-11-21 | 7.6 High |
| Dell EMC CloudLink 7.1.3 and all earlier versions, Auth Token is exposed in GET requests. These request parameters can get logged in reverse proxies and server logs. Attackers may potentially use these tokens to access CloudLink server. Tokens should not be used in request URL to avoid such attacks. | ||||
| CVE-2022-24412 | 1 Dell | 1 Emc Powerscale Onefs | 2024-11-21 | 7.5 High |
| Dell EMC PowerScale OneFS 8.2.x - 9.3.0.x contain an improper handling of value vulnerability. An unprivileged network attacker could potentially exploit this vulnerability, leading to denial-of-service. | ||||
| CVE-2022-24411 | 1 Dell | 1 Emc Powerscale Onefs | 2024-11-21 | 7.8 High |
| Dell PowerScale OneFS 8.2.2 and above contain an elevation of privilege vulnerability. A local attacker with ISI_PRIV_LOGIN_SSH and/or ISI_PRIV_LOGIN_CONSOLE could potentially exploit this vulnerability, leading to elevation of privilege. This could potentially allow users to circumvent PowerScale Compliance Mode guarantees. | ||||
| CVE-2022-24408 | 1 Siemens | 4 Sinumerik Mc, Sinumerik Mc Firmware, Sinumerik One and 1 more | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root. | ||||
| CVE-2022-24402 | 1 Midnightblue | 1 Tetra\ | 2024-11-21 | 8.8 High |
| The TETRA TEA1 keystream generator implements a key register initialization function that compresses the 80-bit key to only 32 bits for usage during the keystream generation phase, which is insufficient to safeguard against exhaustive search attacks. | ||||
| CVE-2022-24401 | 1 Midnightblue | 1 Tetra\ | 2024-11-21 | 8.8 High |
| Adversary-induced keystream re-use on TETRA air-interface encrypted traffic using any TEA keystream generator. IV generation is based upon several TDMA frame counters, which are frequently broadcast by the infrastructure in an unauthenticated manner. An active adversary can manipulate the view of these counters in a mobile station, provoking keystream re-use. By sending crafted messages to the MS and analyzing MS responses, keystream for arbitrary frames can be recovered. | ||||
| CVE-2022-24400 | 1 Midnightblue | 1 Tetra\ | 2024-11-21 | 7.5 High |
| A flaw in the TETRA authentication procecure allows a MITM adversary that can predict the MS challenge RAND2 to set session key DCK to zero. | ||||
| CVE-2022-24396 | 1 Sap | 1 Simple Diagnostics Agent | 2024-11-21 | 7.8 High |
| The Simple Diagnostics Agent - versions 1.0 up to version 1.57, does not perform any authentication checks for functionalities that can be accessed via localhost on http port 3005. Due to lack of authentication checks, an attacker could access administrative or other privileged functionalities and read, modify, or delete sensitive information and configurations. | ||||
| CVE-2022-24394 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “update_checkfile” value for the “filename” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||
| CVE-2022-24393 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “check_vertica_upgrade” value for the “cpIp” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||
| CVE-2022-24392 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “feed_comm_test” value for the “feed” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||
| CVE-2022-24391 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in Fidelis Network and Deception CommandPost enables SQL injection through the web interface by an attacker with user level access. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||
| CVE-2022-24390 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||
| CVE-2022-24389 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in rconfig “cert_utils” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||
| CVE-2022-24388 | 1 Fidelissecurity | 2 Deception, Network | 2024-11-21 | 8.8 High |
| Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability. | ||||