authenticate control commands sent over 433.92 MHz, which allows an attacker to
replay the static commands to impersonate activity. The attacker can also disarm or arm the
system at will if a Nexsmart keypad (product link) is in use, thus compromising
the functionality of the alarm system completely.
Analysis and contextual insights are available on OpenCVE Cloud.
Vendor Solution
Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart through its official support channels and ask about any current remediation guidance.
Tracking
Sign in to view the affected projects.
No advisories yet.
Thu, 19 Nov 2026 10:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to impersonate activity. The attacker can also disarm or arm the system at will if a Nexsmart keypad (product link) is in use, thus compromising the functionality of the alarm system completely. | |
| Title | RF Replay of control commands | |
| Weaknesses | CWE-294 | |
| References |
| |
| Metrics |
cvssV4_0
|
Subscriptions
No data.
Status: PUBLISHED
Assigner: ENISA
Published:
Updated: 2026-11-19T10:30:43.109Z
Reserved: 2026-08-31T12:26:22.054Z
Link: CVE-2026-82948
No data.
No data.
No data.
OpenCVE Enrichment
No data.
-
CWE-294
Authentication Bypass by Capture-replay